R2G-5420P4V - Zippy Technologies R2G-5420P4V 2U Redundant Power Supply. Form Factor: 2...
Request Quote
For Price
- Part Number:
- R2G-5420P4V
- Model Number:
- R2G-5420P4V
- Make:
- ZIPPY TECHNOLOGY
- Lead Time:
- Available
- Qty In Stock:
- Available
Zippy Technologies R2G-5420P4V 2U Redundant Power Supply. Form Factor: 2 Rack Units Redundant (2U Redundant) | Wattage: 420W | Input: PFC Simple Type: Power Supply
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- Cooling: Two 40 Mm Dc Fans (One In Each Module)
- Dielectric Withstanding: Input/Output 1500 Vac For 1 Minute
- Dimension: 276 X 101 X 82 (D*W*H) Mm
- Dimensions (DxWxH): 10.87"/276mm x 3.98"/101mm x 3.23"/82mm
- Efficiency: 70% Typical, At Full Load
- Emi Noise Filter: Fcc Class B, Cispr22 Class B
- Faulty Alarm Methods: Led, Buzzer, Ttl Signal
- Form Factor: 2 Rack Units Redundant (2U Redundant)
- Hold Up Time: 16 Ms Minimum At Full Load & 90 Vac Input Voltage
- Hot-Swappable/Hot Pluggable Redundancy Function
- I2c Features (Optional)
- Input To Fram Ground 1500 Vac For 1 Minute
- Input: PFC
- Isolation: Built-In The Power Module
- Meet Iec-1000-3-2 Class D (Active Pfc)
- N+1 Balance Load Sharing Design On 5/12/3.3v Channel
- Over Load Protection: 110 ~ 160% Max
- Over Voltage Protection:+5v- 5.7v ~ 6.5v, +3.3v- 3.9v ~ 4.3v, +12v- 13.3v ~ 14.3v
- Power Good Signal: On Delay 100 Ms To 500 Ms, Off Delay 1 Ms
- Remote On / Off Control
- Remote Signal Design
- Safety: Meet Ul 60950, Csa 60950, Tuv En-60950
- Short Circuit: 5v, 12v, 3.3v, Auto-Recovered: 5vsb, -12v
- Temperature Range: Operating 0C --- 40C, Storage -20C --- 70C
- Wattage: 420W
Specifications
- +12V1 VDC: Output Current Min:2 Output Current Max:26 Output Current Peak:- Regulation Load:±5% Regulation Line:±1% Output Ripple & Noise Max:120
- +3.3 VDC: Output Current Min:1 Output Current Max:20 Output Current Peak:- Regulation Load:±5% Regulation Line:±1% Output Ripple & Noise Max:50
- +5 VDC : Output Current Min:1 Output Current Max:24 Output Current Peak:- Regulation Load:±5% Regulation Line:±1% Output Ripple & Noise Max:50
- +5 Vsb DC: Output Current Min:0.1 Output Current Max:3 Output Current Peak:- Regulation Load:±5% Regulation Line:±1% Output Ripple & Noise Max:50
- -12 VDC: Output Current Min:0.05 Output Current Max:0.80 Output Current Peak:- Regulation Load:±5% Regulation Line:±1% Output Ripple & Noise Max:150
- Input (PS): VOLTAGE: 90 ~ 264 VAC FULL RANGE. FREQUENCY: 47 ~ 63 Hz. INPUT CURRENT: 4A (RMS) FOR 230 VAC 8A (RMS) FOR 115 VAC INRUSH CURRENT: 50A MAX. FOR 115 VAC PER MODULE 100A MAX. FOR 230 VAC PER MODULE
Applications
- None Available
Aliases
- None Available